Chroma System Solutions, Inc. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
8802 Leakage Test System | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Chroma is the industry's leading supplier of automatic power supply test systems for production, engineering and quality verifications of power supplies. User's may choose from a library of pre-written tests or create their own. Software includes powerful report, statistics and management functions. Systems are factory configured to match customer's test requirements from a large selection of available test instruments, with many thousands currently in use in production and engineering characterization testing. Chroma’s Electrical Double Layer Capacitor Leakage Current Monitoring System model 8802 is the ultimate solution for EDLC (electrical double layer capacitor) leakage current testing.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]()
Chroma Model
8802
Leakage Tester
|
Key Features
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The Chroma Electrical Double
Layer Capacitor Leakage
Current Monitoring System
model 8802 is the ultimate
solution for EDLC
(electrical double layer
capacitor) leakage current
testing. The system includes
modular monitoring boxes,
and a control software to
offer friend and flexible
setup and multi-tank
control, and a high power
switching-mode rectifier (SMR)
power supply. The design is
adaptable for long time of
EDLC leakage current test
and huge amount of EDLC. The System
includes modular monitoring
boxes. The monitoring box
offers various range of
leakage current meter from
1uA-100mA. Each channel has
individual 0 ohm input
resistance leakage current
meter. It suits the EDLC's
low internal resistance
characteristic and avoid
that the meter existent
effect inaccuracy leakage
current measured. The box
offers three circuits,
charge, discharge and
leakage current measurement
circuit. Operators can
finish the whole process in
one system. Charge and
leakage current circuit have
design for reducing the
charge voltage alterable
affection and increasing
charge full voltage time. It
offers 1A maximum charge /
discharge per channel. The
box offers leakage current
GO/NG indications in front
panel for each channel. The
leakage current GO/NG
indications will be
automatic latched before
enter discharge mode.
Operators are easy to see
every DUT test result for
picking up pass or fail.
The System includes Windows®
base control soft-panel. The
soft-panel has multi-tank
control capability. It
offers sequence timing
control base on one tank
with setup time for charge,
measurement leakage current,
and discharge. The process
bar is easy for operators to
see the test process.
Operators can set current
limit values of leakage
current, charge current, and
discharge current through
the soft-panel. The system
has 2.5V-6.0V charge voltage
programmable capability. The system includes a high power switching-mode rectifier (SMR) power supply. It offers a static state charge voltage to reduce the tiny voltage variation to speed up the leakage current result arrive and increate the leakage
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||