Chroma is the global leader in DC Electronic Load manufacturing. Used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, fuel cell testing, Chroma's electronic loads come standard with either USB or RS232 control and can be configured for GPIB (IEEE-488) control as well.
Chroma's 63600 Series DC Electronic Loads are designed for testing multi-output AC/DC power supplies, DC/DC converters, chargers, batteries, adapters, and power electronic components. Excellent for research, development, production, and incoming inspection applications. The 63600's state of the art design uses DSP technology to simulate non-linear loads using an unique CZ operation mode allowing realistic loading behavior. The 63600 series can draw its full rated current to almost zero volts. This unique feature guarantees the best loading performance for fuel cells and modern Point-of-Load devices.
More on this DC Load
PLEASE NOTE: The 6310 has been renamed the 6310/A Series due to the addition of 6 New Features.
New Features Added:
The Chroma 6310A series Programmable DC Electronic Load is suitable for the test and evaluation of multi-output AC/DC power supplies, DC/DC converters, chargers, and power electronic components. It is ideal for applications in research and development, production, and incoming inspection. The system is configured by plugging the user selectable load modules into the system mainframe. The user interfaces include an ergonomically designed user friendly keypad on the front panel and the following computer interfaces: RS-232, USB or GPIB.
The 6310A series offers 8 types of modular loads with power ratings from 100 watts to 1,200 watts, current ratings from 0.5mA to 240A, and voltage ratings from 0.5mV to 500V. The loads can be operated in constant current, constant voltage, constant power and constant resistance and may be placed in parallel for increased current and power.
More on this DC Load| Model | Description | Quote | Buy |
| 6312/A | Mainframe for 2 Load Modules | ||
| 6314/A | Mainframe for 4 Load Modules | ||
| 63101/A | DC Load Module 40A/80V/200W | ||
| 63102/A | DC Load Module 20A/80V/100Wx2 channels | ||
| 63103/A | DC Load Module 60A/80V/300W | ||
| 63105/A | DC Load Module 10A/500V/300W | ||
| 63106/A | DC Load Module 120A/80V/600W | ||
| 63107/A | DC Load Module 4A & 40A/80V/30W & 250W | ||
| 63108/A | DC Load Module 20A/500V/600W | ||
| 63110A | NEW! LED Simulating DC Load Module, 2A/300V/100Wx2 Channels | Call | |
| 63112/A | DC Load Module 240A/80V/1200W | ||
| 63113/A | NEW! LED Simulating DC Load Module, 2A/300V/300W | Call |
The 63200 Series Electronic Loads are designed for DC Power Supply, power electronic devices and components testing. The high power rating, parallel and synchronization capabilities make them the ideal tool for testing the high power UUT such as SMR, UPS, battery, and fuel cell.
The 63200 series offers 10 different models with power range from 2600 watts to 15600 watts, current from 50A to 1000A and up to 500V input voltage. The 4 load modes setup provide different load simulations for various application occasions. The CC/CR modes are designed to test constant voltage type of power supply. CV mode is used to test battery charger and current source, while CP mode is ideal for battery testing by simulating the real discharge curve.
More on this DC Load
Chroma's 6330 loads are enhanced versions of the 6310 series. These loads are packaged and rated identically to the 6310 series except they have been enhanced for automated testing. Enhancements include synchronized paralleling allowing from transient response testing using parallel load groups and high speed data transfer circuits allowing for global queries of voltage and current.Up to eight independent channels maybe configured into a single mainframe. Instruments come standard with front panel controls & RS232 or optional GPIB. Loads modules are available from a wide range covering 0.1VDC to 500VDC, up to 240A and 1200W.
As a result of the exploding increase in CPU complexity according to Moore's Law, all modern processors require a low voltage with high instantaneous current power source. Voltage Regulator Modules, along with embedded solutions, are the only way to correctly supply these currents. A need to simulate this low voltage, high current with fast di/dt loading has become more important than ever. Every main board design using a VRM, Intel ItaniumTM power pod or an embedded regulator (VRD) will need processor voltage supply performance qualification.
Integrating Intel's latest high di/dt test technology with years of experience in the design and manufacture of highly accurate, precision DC load and measurement instrumentation, the Chroma 63472 electronic load is your total solution for qualifying all main board Intel® processor power performance requirements.
More on this DC Load| Model | Description | Quote | Buy |
| 63472 | High Slew Rate Load Control & Measurement Unit | Call |
Our experienced sales engineers can help you select the right instrument for your application. Contact Chroma Systems Solutions today!