| 6310A
Series Modular DC Electronic Load |
|
 |
Download datasheet
See all loads |
|
| About the 6310A |
|
The Chroma 6310A series Programmable DC Electronic Load is suitable for the test and evaluation of multi-output AC/DC power supplies, DC/DC converters, chargers, and power electronic components. It is ideal for
applications in research and development, production, and incoming inspection. The system is configured by plugging the user selectable load modules into the system mainframe. The user interfaces include an ergonomically designed user friendly keypad on the front panel and the following computer interfaces: RS-232, USB or GPIB.
The 6310A series offers 8 types of modular loads with power ratings from 100 watts to 1,200 watts, current ratings from 0.5mA to 240A, and voltage ratings from 0.5mV to 500V. The loads can be operated in constant current,
constant voltage, constant power and constant resistance and may be placed in parallel for increased current and power.
The 6310A series can simulate a wide range of dynamic loading applications. The waveforms programmable parameters include: slew rate, load level, duration and conducting voltage. Also, up to 100 sets of system operating status can be stored in EEPROM and recalled instantly for automated testing applications.
Real time measurement of voltage and current are integrated into each 6310A load module using a 16-bit precision measurement circuit. The user can perform on line voltage measurements and adjustments or simulate short circuit test using the user friendly keypad on the front panel. Additionally, the 6310A series offers an optional remote controller for
automated production lines.
The 6310A series has a self-diagnosis routine to maintain instrument performance. It also provides OP, OC, OV, OT, and reverse polarity protection to guarantee quality and reliability for even the most demanding engineering testing and ATE applications. |
|
| |
|
| Module Load Design |
|
The 6314A holds up to four 63102A load modules, which will result in an 8-channel 100W/channel load with standard front-panel inputs. This makes it ideal for testing multiple output switching power supplies and multiple DC-DC converters. |


|
|
| |
|
| Application of Specific Load Simulation
|
The 6310A load modules operate in constant current, constant voltage, constant power or constant resistance to satisfy a wide range of test requirements. For example, the test of a battery charger can be simulated easily by setting the load to operate in constant voltage. |
|



|
|
| |
|
| Dynamic Loading and Control
|
The 6310A loads offer high speed, programmable dynamic load simulation and control capability. The figure below shows the programmable parameters of the 6310A modules: |
|
 |
|
| The programmable slew rate makes the simulation of transient load change demanded by real life applications possible. The 6310A internal waveform generator is capable of producing a maximum slew rate at 10A/µs, and dynamic cycling up to 20kHz. |
|
| |
|
| Parallel Control |
| The 6310A provides parallel control, which enables high power testing when a single module cannot meet the requirement of high power applications. Two or more load modules can be paralleled together to achieve the desired loading. The 6310A comes with RS-232 as standard for remote control and automated testing applications. The USB and GPIB interfaces are available as options. |
|
| |
|
| Powerful Measurements
|
|
Each 6310A load module has an integrated 16-bit precision A/D converter for voltage measurement with an accuracy of 0.025%+0.025% of full scale. The built-in resistive load current sensing circuit is capable of measuring current with an accuracy of 0.05%+0.05% of full scale. |
|
| |
|
| OCP Test
|
|
By simply choosing the channel and setting the OCP parameters (start current, end current, step current and dwell time) from the front panel, the 6310A series provides a fast and easy OCP testing solution. The 6310A series will automatically detect the OCP point, making it an ideal solution for design verification as well as production line testing.
|
|
 |
|
| |
|
| Timing Function
|
|
| The 6310A series of loads include a unique timing & measurement function, which allows precise time measurements in the range of 1ms to 86,400s. This feature allows the user to set the final voltage & timeout values for battery discharge testing and other similar applications. |
|
 |
|
| |
|
| Digital I/O |
|
| The digital I/O interface makes the 6310A DC Load the ideal choice for automated testing requirements. Through the digital I/O, the 6310A can accept digital signals to trigger its functions (Load On/Off, OCP test, etc.) as well as current output status signals. |
|
 |
|
| |
|
| 6310A Series Programmable DC Electronic Load Family |
|
 |
|
| |
|
|
|
|
|
| 6312A |
Mainframe for 2 Load Modules |
Quote it |
 |
| 6314A |
Mainframe for 4 Load Modules |
Quote it |
 |
| 63101A |
DC Load Module 40A/80V/200W |
Quote it |
 |
| 63102A |
DC Load Module 20A/80V/100Wx2 channels |
Quote it |
 |
| 63103A |
DC Load Module 60A/80V/300W |
Quote it |
 |
| 63105A |
DC Load Module 10A/500V/300W |
Quote it |
 |
| 63106A |
DC Load Module 120A/80V/600W |
Quote it |
 |
| 63107A |
DC Load Module 4A & 40A/80V/30W & 250W |
Quote it |
 |
| 63108A |
DC Load Module 20A/500V/600W |
Quote it |
 |
| 63112A |
DC Load Module 240A/80V/1200W |
Quote it |
 |
| 63110A |
NEW LED Simulating DC Load Module, 2A/300V/100Wx2 channels |
Quote it |
 |
|
| |
|
© 2009 Chroma Systems Solutions, Inc. / COOLBURN® is a registered trademark of Chroma Systems Solutions, Inc. |
|
|
Our experienced sales engineers can help you select the right instrument for your application. |
| 949-600-6400 |
| Contact sales |
Contact service |
| Request a quote |
Join our e-mailing list to get new product releases, news, and our quarterly report. |
| Subscribe |
| |
| Search site |
|
|
|
|
 |
|
New Standard for Low Power Programmable AC Power Sources |
The 61500 series defines a new standard of lower power AC power sources. Features included are power line disturbance simulation, programmable output impedance, comprehensive measurement functions and wave shape synthesis.
Provides 0-300VAC or 0-424VDC output from a single source. Ultra-pure/low distortion output for designed for commercial applications.
Smaller, lighter and expanding setting and read-back functions.
Provides 6:1 peak current capability and includes power amplifier mode. |
|
|
 |
Meets Energy Star Measuring Requirements |
The 66201 Digital Power Meter is packaged in a 2U high, half rack enclosure suitable for bench top or system integration and includes simple measurement functions designed for low power applications (maximum current 2A).
Model 66202 Digital Power Meter includes a 2-shunt design to provide highly accurate readings for both low and high current measurements. In addition to the parameters measured by Model 66201, the 66202 includes Inrush current, Total Harmonic Distortion of V/I, and Energy measurements. With these practical functions, The Model 66202 is suitable for the most demanding of R&D and quality control departments.
|
|
|