| Auto Frequency SWP for Dynamic Testing |
|

|
|
Testing the SMPS dynamic loading and acquiring the maximum of Vpk+ and Vpk- (at worse case) from 50Hz ~ 10kHz.
Example: The PC power supply after R&D phase must be certified by DQC using the Electronic Load’s CC Dynamic mode to validate the worse case of transient response and voltage peak under the combination of loading level, frequency and duty condition. Using an Oscilloscope to capture Vpk+/- manually for 100 kinds of combinations is very time consuming, so the Dynamic Sweep function is built in for the new generation of Load. Simply setting the initial frequency, end frequency and step frequency can complete loading and measurement automatically. The maximum dot of occurrence frequency Vpk+ & Vpk- is displayed after execution. |
|

|
| |
|
|
|
|
| 63600-1 |
63600 Mainframe for Single Modules |
Quote it |
 |
| 63600-2 |
63600 Mainframe for up to 2 Modules |
Quote it |
 |
| 63600-5 |
63600 Mainframe for up to 5 Modules |
Quote it |
 |
| 63610-80-20 |
DC Load Module, 100W x 2/ 80V/ 20A |
Quote it |
 |
| 63630-80-60 |
DC Load Module, 300W/ 80V/ 60A |
Quote it |
 |
| 63640-80-80 |
DC Load Module, 400W/ 80V/ 80A |
Quote it |
 |
|
| |
|
Home | Company | Careers | Products | Support | Services | Training | Request Quote | Contact
© 2009 Chroma Systems Solutions, Inc. / COOLBURN® is a registered trademark of Chroma Systems Solutions, Inc. |
|
|
Our experienced sales engineers can help you select the right instrument for your application. |
| 949-600-6400 |
| Contact sales |
Contact service |
| Request a quote |
Join our e-mailing list to get new product releases, news, and our quarterly report. |
| Subscribe |
| |
| Search site |
|
|
|
 |
Measure Critical Timing Parameters: UPS, Battery, Off-grid Inverters |
Chroma's 63800 AC Electronic Loads are designed for testing uninterruptible power supplies (UPS), Batteries, Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors. Equipped with unique timing measurement functions, the 63800 Loads allow users to measure critical timing parameters such as battery discharge time, the trip time for fuse and breaker testing and UPS transfer time. |
|
|
 |
Meets Energy Star Measuring Requirements |
The 66201 Digital Power Meter is packaged in a 2U high, half rack enclosure suitable for bench top or system integration and includes simple measurement functions designed for low power applications (maximum current 2A).
Model 66202 Digital Power Meter includes a 2-shunt design to provide highly accurate readings for both low and high current measurements. In addition to the parameters measured by Model 66201, the 66202 includes Inrush current, Total Harmonic Distortion of V/I, and Energy measurements. With these practical functions, The Model 66202 is suitable for the most demanding of R&D and quality control departments.
|
|
|