| DC Electronic Load Comparison Table | |||||
| 63600 Series | 6310/A Series | 6330 Series | 63200 Series | 63472 Series | |
![]() |
![]() |
![]() |
![]() |
![]() |
|
| Max Power Range | Up to 2000W | Up to 1200W | Up to 1200W | Up to 15.6 W Parallelable to +40KW | 200W |
| Max No. of Outputs | 10 | 8 | 8 | 1 | 1 |
| Max Current | 300A | 240A | 240A | 1000A | 150A |
| Operating Range* | 0-500V | 0-500V | 0-500V | 0-500V | 0.5-2V |
| Modes of Operation | CC, CR, CV, CP, CZ | CC, CR,CV | CC, CR,CV | CC, CR, CV, CP | CC |
| CC Accuracy | 0.1% + 0.1%FS | 0.1% + 0.2% FS | 0.1% + 0.1% FS | 0.1% + 0.2% FS | |
| CR Accuracy | 0.1% | 0.35% | - | ||
| CV Accuracy | 0.05% + 0.1%FS | 0.05% + 0.1% FS | - | ||
| CP Accuracy | 0.3%FS | 2%FS | 0.5% + 0.5% FS | - | |
| Dynamic Mode | To 50KHz | To 20KHz | To 1MHz | ||
| Max Slew Rate (di/dt) | 8A/µS | 10A/µS | 25A/µS | 1000A/µS | |
| Dynamic Paralleling | Yes | Yes | Yes | Yes | No |
| Special Features | Const CZ modeDigitized V&I | Flexible CC, CR, CP and CV operation modes | Faster data rates for ATE applications | External loading waveform simulation. | For VRM applications |