Exploring Battery Cell Insulation Tester

Battery Cell Insulation Tester-Chroma 11210

Battery Cell Insulation Tester

Chroma 11210

Accurately measure leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials.

Test Voltage

Up to 1KV(DC)

Charge Current

50mA max.

IR (Insulation Resistance)

0.01kΩ~10 TΩ [kΩ, MΩ, GΩ]

Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.

PD Detection and Measurement Function

Chroma 11210 battery cell insulation tester detects any PD or flashover that may occur inside the battery cells. There are two phases of detection that the 11210 employs with different circuitries used. The first phase is in CC (Constant Current) mode when the 11210 charges the DUT with a constant current set by the user. During this mode, the 11210 will monitor the voltage level and its slope. Any glitches on the voltage slope or any unexpected changes of the slope will be detected by the 11210 and reported as PD occurrences.

The second phase is in CV (Constant Voltage) mode. In this mode, only a stable leakage current should exist. Thus any unusual and protruding pulses on the current waveform are typically the result of an abnormal discharge (i.e. PD or flashover) which will also be detected and reported by the 11210 as a PD occurrence. Chroma 11210 not only detects, but also roughly measures the magnitude of the PD pulses during these modes.

Capacitor Test Applications with 11210

Chroma 11210 is the next generation and advanced version of its predecessor the Chroma 11200 capacitor LC/IR meter. The 11210 includes more versatile functions with higher accuracy, however, retains all the major functions and capabilities found in the 11200. Therefore, the 11210 is also an advanced LC/IR meter for all types of capacitors. In the production line, the 11210 is able to test capacitors at a very high speed (~20ms per DUT) with appropriate fixtures.

Moreover, it has a very wide range of LC/IR measurement with excellent accuracy. Chroma 11210 is the new standard insulation inspection and test instrument for all capacitor production lines.

More Features

Automatic Test with Sequence: Charge-Dwell-Measure-Discharge

High Speed Testing
(20ms/device)

Full-Color Display
and Touch Panel

Handler, USB, RS-232,
Ethernet Interfaces

With PD detection of the battery’s internal status before electrolyte filling, defective products can be filtered out before entering the next stage of production preventing the potential hazards that may occur in the field. In contrast to traditional methods of insulation test, Chroma 11210 provides an entirely new concept for inspection and evaluation of battery quality.

Model Options

ModelDescription
11210Battery Cell Insulation Tester
A112100Partial Discharge Detection Card
A112101Partial Discharge Analyzer Card
A112102PD Test Checking Kit
A112103Handler Interface Converter Box

Watch

A Better Insulation Test: Decreasing Risk of Electrical Shorts in Lithium Ion Battery Cells

This seminar covers new testing procedures and equipment to monitor voltage and current in order to detect minor partial discharge or flashover inside the cell resulting in lower risk to the manufacturer and end user.

BDV & PD Functions

This video takes you through the various BDV and PD functions and settings that the 11210 Battery Insulation Tester features.
Play Video
Play Video

Improve Li-ion Battery Safety

Chroma 11210 Battery Cell Insulation Tester detects abnormal insulation of lithium-ion batteries (dry cells), offering two unique technologies that other available withstand voltage or insulation testers lack. The test device not only monitors the entire test process for electrical flashover due to abnormal partial discharge but also quantifies it and creates recordable waveforms.

Battery Cell Insulation Tester

Chroma 11210 Battery Cell Insulation Tester detects abnormal insulation of lithium-ion batteries (dry cells), offering two unique technologies that other available withstand voltage or insulation testers lack. First, the test device not only monitors the entire test process for electrical flashover due to abnormal partial discharge but also quantifies it and creates recordable waveforms. Moreover, after reaching the test voltage, the leakage current or insulation resistance are measured and judged during the test time as with WV/IR testers.

Related Products

Guardian Multi-Channel Hipot Tester

Chroma 19020

AC or AC / DC / IR

10 (up to 100)

AC: 0.05kV~6kV
DC: 0.05kV~8kV

Measure the hipot leakage current of all channels at the same time and conduct tests on up to 100 DUTs simultaneously

Guardian Hipot Tester AC/DC/IR/SCAN

Chroma 19050

AC / DC / IR
or AC / DC / IR / SCAN

1, 4 or 8

AC: 0.05~5kV
DC: 0.05~6kV

Advanced digital hipot testers with load and line regulations that help ensure measurement integrity, and Multi-step capability allows users to perform multiple tests in sequence

Guardian Hipot Analyzer

Chroma 19055

AC: 0.05~5kV
DC: 0.05~6kV

AC: 5kV/100mA (4kV/120mA)
DC: 25mA

0.1MΩ~50GΩ / 5kV max

Designed for hipot tests and analysis of transformers, motors and other electronic components

Guardian Hipot Analyzer

Chroma 19056/19057

AC: 0.1~10kV (19056)
DC: 0.1~20kV (19057)

AC: 20mA (19056)
DC: 10mA (19057)

0.1MΩ~50GΩ / 5kV max

Provides high withstand voltage test and analysis for optical couplers, HV relays, HV switches, and PV modules components, which have better insulation capability