Exploring Battery Reliability Test System
Chroma’s Battery & Reliability Test System is a high-precision system designed specifically for testing lithium-ion battery (LIB) cells, electric double-layer capacitors (EDLCs), and lithium-ion capacitors (LICs).
Output and Measurement
Up to ±0.015% of full scale
Current Response
Up to 100µS
Sampling Rate
Up to 10mS
• Quick switching of current ranges: Chroma 17010 series provide multiple current outputs and measurement range switching, fitting test plans with both large and small currents. At the start of a test step, the system will detect the output current and then automatically and quickly switch to the appropriate current range. This improves the test accuracy and resolution for highly accurate test data.
• Automatic range switching under constant voltage mode: Chroma 17010 linear circuit models support automatic switching of the current range in the constant voltage test mode, without any output interruption. This is perfect for applications such as float charging or potential regulation, which require long-term and highly stable testing of extremely small current output.
Chroma 17010 uses high-speed voltage and current sampling with double integration of computing to capture transient changes in the test without distortion. The advanced test system provides more accurate capacity calculations to solve the issue that general battery test equipment only use the report sampling speed to record key data, causing large cumulative errors.
• Hardware internal voltage/current sampling rate: 1mS
• Report single point transient sampling rate: 1mS
• Report sampling rate: 10mS
Chroma 17010 system provides three safety mechanisms: software/hardware detection, equipment abnormality monitoring, and optional independent relay hardware detection to ensure the safety of LIB cells tests.
Model Options
Model | Description |
17216-6-6 | Programmable Charge/Discharge Tester (6V/6A) Current Range: 6A/1.2A/0.6A/1mA | Power Range: 0-6V | Channels: 16/32/48/64/80/96 |
17216-6-12 | Programmable Charge/Discharge Tester (6V/12A) Current Range: 12A/2.4A/1.2A/1mA | Power Range: 0-6V | Channels: 16/32/48/64/80/96 |
17216M-10-6 | Programmable Charge/Discharge Tester (10V/6A) Current Range: 6A/0.2A/6mA/0.2mA | Power Range: 0-10V/0-5V/±5V | Channels: 16/32/48/64/80/96 |
17216M-6-12 | Programmable Charge/Discharge Tester (6V/12A) Current Range: 12A/3A/1A/0.1A | Power Range: 0-6V | Channels: 16/32/48/64/80/96 |
17208M-6-30 | Programmable Charge/Discharge Tester (6V/30A) Current Range: 30A/10A/0.1A/1mA | Power Range: 0-6V | Channels: 8/16/24/32/40/48/56/64 |
17208M-6-60 | Programmable Charge/Discharge Tester (6V/60A) Current Range: 60A/15A/5A/0.5A | Power Range: 0-6V | Channels: 8/16/24/32/40/48/56/64 |
17212M-6-100S | Programmable Charge/Discharge Tester (6V/100A) Current Range: 100A/50A/25A | Power Range: 0-6V | Channels: 12/24/36/48 |
A170103 | Battery Cell Test System Auto Calibrator Current: 120A | Voltage: 0-10V | Channels: 16 |
Chroma Battery Reliability Test System | 17010
Learn How Battery Pro Can Help with Charge-discharge Testing in Real-time
19772 Pauling
Foothill Ranch, CA 92610
Tel: 949-600-6400
Fax: 949-600-6401