How to setup “single phase” or “three phase” output with 61500/61600 Series AC Power Sources.

The 61511/12, 61611/12 AC Power Sources all have the same type of output terminations. The output can be “Three Phase” or “Single Phase” selectable. This allows the customer to use their system as follows:

  • 61511 or 61611: “Three Phase” Output Maximum Power 4Kw per Phase (12Kw total)
  • 61511 or 61611: “Single Phase” Output Maximum Power 12Kw
  • 61512 or 61612: “Three Phase” Output Maximum Power 6Kw per Phase (18Kw total)
  • 61512 or 61612: “Single Phase” Output Maximum Power 18Kw

The output can supply Three Phase” or “Single Phase” power. To select “Three Phase” or “Single Phase” output you simply press the “Phase” button on the front panel. The drawing below shows the Output Terminal Block including the Remote Sense Terminal Block. For “Three Phase” the Output connections are Ø1, Ø2, Ø3 with Neutral (N) and Ground. For “One Phase” the Output connections are Line (L) (Ø2) and Neutral (N) and Ground.