Latest News

Chroma’s Wound Component Analyzer Combines Many Tests

Chroma Systems Solutions, Inc.,  announces the industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1. Its 500VA design is also compliant with the output power requirements of EC/UL. Wound component applications include EV motors, servomotors, ascension motors, transformers and solenoid valves.

Chroma 19036 Wound Component Electrical Safety Test (EST) Analyzer
Chroma’s new Wound Component Electrical Safety Test (EST) Analyzer.

Chroma’s 19036 Wound Component EST Analyzer impulse winding test imposes a non-destructive, high speed and low energy voltage impulse on the device under test for analysis and comparison. The purpose of impulse winding test is to discover potential defects such as layer short, corona or partial discharge usually difficult to find in wound components during early phases of design and production. Analysis of the impulse test can be determined by Area Size, Differential Area, Flutter Value or Laplacian method.

The 19036 is equipped with a patented 4-wire DC resistance test that has both Drive and Sense in compliance with withstanding specification and provides 10 channels of 4-wire DC resistance test functions. Up to 40 channels of scanning test can be conducted when the 19036 is configured with the optional 16 channel external HV scan boxes.

The 19036 includes Flashover Detection built-in. Flashover is an electrical breakdown of a gas that produces an ongoing plasma discharge, resulting from a current flowing through normally nonconductive media such as air. Since flashover cannot be simply detected by the leakage current rms value, the Flashover Detection feature is an invaluable part of the HV test. For Contact Checking during the hipot test, the 19036 is equipped with a High Frequency Contact Check (HFCC). By conducting the Contact Check during Hipot test, it can increase the test reliability and efficiency significantly by identifying test fail problems caused by bad contact of cabling or the test fixture. For more information on these testers, logon to https://chroma1.wpengine.com/hipot-safety-testers/19036-wound-component-est-analyzer.php or call us at (949) 600-6400.

More Recent Posts

Ensuring EV Charging Safety: Chroma Delivers IEC 61851-23 Compliant Test Solutions for DC EV Supply Equipment

Chroma’s EVSE Automated Test System (ATS) 8000 is built around in-house developed components, including the software platform, power sources and electronic loads, communication control unit, and other key modules. This supports test requirements for DIN 70122, ISO 15118-4, and ISO 15118-5 communication conformance as well as electrical parameter verification.

Read More »

Chroma 17050 Offers a Comprehensive BBU Testing Solution

The Chroma 17050 is not only a BBU testing system but also sets a new benchmark for BBU performance- driving the data center industry towards higher efficiency, intelligence, and green energy. Through flexible recipe editing, rapid data acquisition, and real-time monitoring, it helps users comprehensively improve the efficiency and quality of BBU testing.

Read More »

Chroma 1.8MW Bidirectional Power Supply Accelerates the HVDC Era

In AI workloads, instantaneous power surges demand uncompromised reliability, as any brief drop in power can undermine GPU computation. To address this demand, Chroma developed the 62450D-2000HL, a bidirectional DC power supply and regenerative electronic load purpose-engineered for high-voltage, high-power testing.

Read More »